Solar & Battery Installation for Madginford Hall, Maidstone

  • The result

    Madginford Hall now has a 14.1 kWp solar and battery system designed to reduce reliance on grid electricity while providing whole-building backup during a power outage.

    The system is estimated to cover around 86% of the hall’s annual electricity requirement and deliver approximately £2,064 in electricity savings and export income in year one.

    The estimated payback is based on the full project cost, despite the installation itself being fully funded through National Lottery funding.

    At a glance

    1186

    Community & leisure / charity

    14.1 kWp

    30 × AIKO Neostar 3S 470W

    2 × Fox ESS EP12 – approx. 23 kWh total

    Approx. 5,500 kWh

    12,368 kWh

    Approx. £2,064

    9 years

    2,475 kg per year

    Approx. 86%

    Approx. 40%

    The client’s objective

    Backup power was a meaningful part of the brief rather than simply an optional addition.

    The system is designed to provide whole-hall backup within the 10 kW inverter capacity and the available battery charge.

    As an illustration, Phase Energy estimates that if the batteries were fully charged and the hall restricted electricity demand to around a 2 kW critical load, the stored energy could support that level of demand for approximately 10 hours.

    Actual backup duration would depend on battery state of charge and the electrical loads being used during the outage.

    The Phase Energy solution

    We designed a 14.1 kWp solar PV system using 30 AIKO Neostar 3S 470W panels across the building’s east- and west-facing roof areas.

    The array was paired with a Fox ESS KH 10kW hybrid inverter and two Fox ESS EP12 11.52 kWh batteries, providing approximately 23 kWh of battery storage.

    A Fox ESS backup system was also incorporated so that the hall can continue to receive power during a grid outage, within the capabilities of the inverter, the available battery charge and the electrical demand at the time.

    Why the system was designed this way

    The panel layout makes use of both the east- and west-facing roof areas, allowing solar generation to be spread across more of the day.

    The client selected the larger battery capacity to provide greater storage and resilience.

    Battery storage also complements the site’s grid connection arrangements. The DNO approval included a 6.5 kW export limit, so storing more of the electricity generated on site gives the hall greater opportunity to use that energy rather than relying solely on export.

    Installation

    The client wanted the inverter, batteries and associated equipment positioned away from areas accessible to the public.

    Accommodating this requirement added some additional work to the installation, including extra wiring for the Fox ESS backup equipment.

    The project was completed over two days.

    Predicted energy and financial performance

    Existing annual electricity use
    Approx. 5,500 kWh

    Estimated annual generation
    12,368 kWh

    Estimated electricity demand covered by solar
    Approx. 86%

    Estimated solar generation used on site
    Approx. 40%

    Estimated solar generation exported
    Approx. 60%

    Estimated year-one financial benefit
    Approx. £2,064

    Estimated payback
    9 years

    Estimated CO₂ reduction
    2,475 kg per year

    The estimated payback is based on the full project cost, despite the installation itself being funded through National Lottery funding.

    All performance and financial figures are proposal-stage estimates rather than guarantees. Actual results will depend on weather conditions, electricity use, tariffs and battery operation.

    Finance

    The installation was fully funded using National Lottery funding secured by the client.

    The precise funding programme has not yet been confirmed for publication, so I would keep the wording at this level unless Phase Energy receives further details.

    Customer experience

    More Commercial Solar Projects

    • Commercial Solar Installation for Britelite Windows, Maidstone

      A commercial solar system predicted to generate 45,802 kWh a year with a 3–4 year…

      Read More

    • Commercial Solar Installation at Frith Farm, Tadley, Hampshire

      A 71.76 kWp farm solar system predicted to generate 66,039 kWh a year with a…

      Read More

    • Commercial Solar Installation for a Farm in Malton, North Yorkshire

      Estimated to generate 21,259 kWh a year with a five-year payback.

      Read More